Control Techniques SPV systems are a range
of transformerless central inverters for PV installations from
145kWp to 1.76MWp. Each inverter is constructed using multiple
standard 145kWp or 175kW modules.

Intelligent Inverter Management
(IIM)
The modules are controlled by Control Techniques unique
Intelligent Inverter Management (IIM) system to maximise energy
yield by controlling the active and standby status of each inverter
module. The active and standby sequence for each module is rotated
so that duty is shared and inverter life extended. IIM has other
benefits of energy efficiency and increased reliability:
Enhanced efficiency
- Modularity allows the active inverter capacity to be
continuously scaled to optimize energy efficiency for all
conditions
- The system generates energy in lower light
conditions
Enhanced availability
- In the event of any inverter module trip, the system
automatically reconfigures to continue generating.
- For critical applications built-in redundancy can be
incorporated within the system to maintain maximum output
with a small additional investment.
The following graph demonstrates the high efficiency
of the system, which remains above 96% at only 3% of full load.
This compares to conventional bulk inverters where the efficiency
begins to reduce severely below 20% of full load. Yield at low load
is particularly important in temperate climates such as northern
Europe.

High accuracy MPPT algorithm
To ensure maximum power is obtained from PV arrays, Control
Techniques' unique Maximum Power Point Tracking (MPPT) algorithm is
optimized for accuracy for both crystalline and thin film solar
panels. The system is able to adapt rapidly to fast moving weather
conditions across a wide temperature range.
Key inverter features
- High conversion efficiency, 98.0% peak, 97.6% EU factor
- Optimized for reliability and long active life
- Standard industrial mass produced inverter modules
- Power increments of 175kWp from 145kWp to 1.76MWp
- Compact inverter footprint
- Low switch-on point of 900W (0.05% on 1.76MW inverter)
- High accuracy Maximum Power Point Tracking (MPPT) over a wide
voltage range
- Engineered for compliance with international grid connection
codes
- Automatic reactive current and power factor control
- Anti-islanding and supply dip ride-through
- 3.3% total harmonic current distortion (ITHD) - no transformer
de-rating required
- Tolerant to inverter module faults with fast automatic
recovery
- Communications and PC tools for local or remote configuration
and monitoring
Options
- Built in inverter redundancy
- Communications via Ethernet (Ethernet/ IP, Modbus TCP/IP,
TCP/IP web server), Modbus RTU, Profibus DP, Devicenet
- DC fusing or circuit breakers AC / DC side switches +/- DC side
grounding
- Single piece or split AC side / DC side construction
- DC over-voltage protection (use is compulsory)
- Inverter powered shelter cooling fans
- OPC Server
- Utility interface
- Up to 1000V switch-on
Download Control Techniques